| Control method | Stored program iterative operation | 
| Input and output control method | Refresh method | 
| Sequence control language | Relay symbol word, logic symbolic word, MELSAP-II (SFC) | 
| Processing speed Sequence instruction | 0.09µs / step | 
| Constant scan | 10 to 190ms (can be set in units of 10ms) | 
| Memory capacity | 256K bytes (built-in RAM) | 
| I / O device points | 8192 points (X/Y0~1FFF) | 
| Number of input / output points | 1024 points (X/Y0~3FF) | 
| comment | Maximum 4032 points (set in units of 64 points) | 
| Extended comment | Maximum 3968 points (set in units of 64 points) | 
| Output mode switching during STOP → RUN | Reoutput the calculation status before STOP / Select output after execution of calculation | 
| Self-diagnostic function | Computational congestion monitoring Abnormality detection of memory / CPU / input / output / battery, etc. | 
| Operation mode at the time of error | Stop / Continue selection | 
| Start method at the time of RUN | Initial start (When the power is turned on / when the power is restored after a power failure, the CPU automatically restarts when the "RUN" switch is turned on.) | 
| Latch (power failure retention) range | L1000-2047 (default) (Latch range can be set for L, B, T, C, D, W) | 
| RUN / PAUSE contacts | One point can be set for each RUN / PAUSE contact from X0 to 1FFF | 
| Print title registration | Yes (128 characters) | 
| Keyword registration | Yes | 
| Input / output allocation | Input / output occupied points and unit model name can be registered | 
| Step driving | Sequence program operation can be executed and stopped | 
Specifications:
Internal relay [M]:7144 points (M0 to 999, M2048 to 8191) 8192 points in total for M, S, L shared
Latch relay [L]:1048 points (L1000-2047) 8192 points in total for M, S, L shared
Step relay [S]:0 points (no initial state) 8192 points in total for M, S, L shared
Link relay [B:8192 points (B0~1FFF)
Timer [T]:2048 points (default 256 points)
100ms timer (T0 to 199): Set time 0.1 to 3276.7s
10ms timer (T200-255): Set time 0.01-327.67s
100ms integration timer (initially none): set time 0.1-3276.7s
Extended timer (T256 to 2047): Time set by word device (D, W, R)
Counter [C:1024 points (default 256 points)
Normal counter (C0 to 255): Setting range 1 to 32767 times
Interrupt counter (no initial value): Can be set from C224 to 255
depending on the setting
Extended counter (C256 to 1023): Count value set by word device (D, W, R)
 Similer item we can supply:
| Q01CPU | Q02(H)CPU | Q06HCPU | 
| Q12HCPU | Q25HCPU | Q02PHCPU | 
| Q06PHCPU | Q12PHCPU | Q25PHCPU | 
| Q00UCPU | Q01UCPU | Q02UCPU | 
| Q03UDVCPU | Q03UD(E)CPU | Q04UDVCPU | 
| Q04UD(E)HCPU | Q06UDVCPU | Q06UD(E)HCPU | 
| Q10UD(E)HCPU | Q13UDVCPU | Q13UD(E)HCPU | 
| Q20UD(E)HCPU | Q26UDVCPU | Q26UD(E)HCPU | 
| Q50UDEHCPU | Q50UDEHCPU | Q50UDEHCPU | 
| Q01UCPU | Q02CPU | Q02CPU-A | 
Our advantage Products:
 【Honeywell】Module DCS / PLC
 【Emerson】DeltaV Module / Servo Motor
 
 【ABB】Input Output Module
 【AB】Module / Touch Screen
 【Rosemount】Pressure and Temperature Transmitter
 【Yokogawa】Pressure Transmitter
 【Yaskawa】Servo Drive / Servo Motor
 【Mitsubishi】Servo Drive / Servo Motor
 【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
 
 (Modicon,SMC,SICK,NORGREN,Siemens etc.)
 
 Shenzhen Wisdomlong Technology CO.,LTD
 Contact person:Suki
 Email:wtl2502keji@163.com
 Skype:wtl2502
Company website:www.wtltian.com
 Tel:+86-13268302140