Input specification
Input format | DC input (plus common type) |
Number of input points | 16 points |
Rated input voltage | 24V DC (within 5% ripple rate) (permissible voltage range: 19.2 to26.4V DC) |
Rated input current | About 7 mA |
Maximum number of simultaneous input points | 100% |
ON voltage / ON current | 14V or more / 3.5mA or more |
OFF voltage / OFF current | 6 V or less / 1.7 mA or less |
Input resistance | Approximately 3.3 kΩ |
Input response time OFF → ON | 1.5 ms or less (DC 24 V) |
Input response time ON → OFF | 1.5 ms or less (DC 24 V) |
Input isolation method | Photocoupler isolation |
Output specification
Output format | Transistor output (sink type) |
Output points | 16 points |
Rated load voltage | DC24V |
Operating load voltage range | DC 19.2 to 26.4 V (within 5% ripple rate) |
Maximum load current | 0.5A / 1 point, 3.6A / 1 common |
Maximum inrush current | 1.0A 10ms or less |
OFF current leakage current | A0.25 mA or less |
Maximum voltage drop when ON | DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 |
Output response time OFF → ON | 0.5 ms or less |
Output response time ON → OFF | 1.5 ms or less (resistive load) |
Surge killer | Zener diode |
Protection function | Over load protection function, over voltage protection function, over temperature protection function |
Output unit external power supply voltage | DC 19.2 to 26.4 V (within 5% ripple rate) |
Current | 30 mA or less (24 V DC, common) excluding external load current |
Output isolation method | Photocoupler insulation |
|
Common specification
Common method | 32 points 1 common (Terminal trapezoidal 1-wire type) |
Dielectric breakdown voltage | Between DC external terminal block and ground: AC500V 1 minute |
Insulation resistance | Between DC external terminal block and ground: 10 MΩ or more with DC 500 V insulation resistance tester |
Protection grade | IP2X |
Station type | Remote I / O station |
Number of occupied stations | 1 station |
Unit power supply voltage | DC 20.4 to 26.4 V (within 5% ripple rate) |
Current | 60 mA or less (24 V DC, all points on) |
External wiring connection method | Communication unit, unit power supply unit: 7-point 2-piece terminal block (M3 screw) Input / output power supply unit, input / output unit: 34-point direct mount terminal block (M3 screw) |
Dimension height (H) | 50 mm |
Width (W) | 179 mm |
Depth (D) | 40 mm |
mass | 0.25 kg |
Attribute | Value |
---|---|
For Use With | MELSEC Q Series |
Number of I/O | 2048 |
Manufacturer Series | MELSEC Q |
Input Type | Analogue, Digital |
Voltage Category | 5 V dc |
Output Type | Analogue, Digital |
Communication Port Type | RS232C |
Program Capacity | 32 kB |
Programming Interface | Computer, Operating Panel |
Length | 89.3mm |
Maximum Inputs/Outputs | 8192 |
Number of Communication Ports | 1 |
Width | 27.4mm |
Maximum Operating Temperature | +55°C |
Dimensions | 89.3 x 27.4 x 98 mm |
Depth | 98mm |
Battery Backup | Yes |
Minimum Operating Temperature | 0°C |
Mounting Type | DIN Rail |
Memory | 94 kB |
Similer item we can supply:
Q01CPU | Q02(H)CPU | Q06HCPU |
Q12HCPU | Q25HCPU | Q02PHCPU |
Q06PHCPU | Q12PHCPU | Q25PHCPU |
Q00UCPU | Q01UCPU | Q02UCPU |
Q03UDVCPU | Q03UD(E)CPU | Q04UDVCPU |
Q04UD(E)HCPU | Q06UDVCPU | Q06UD(E)HCPU |
Q10UD(E)HCPU | Q13UDVCPU | Q13UD(E)HCPU |
Q20UD(E)HCPU | Q26UDVCPU | Q26UD(E)HCPU |
Q50UDEHCPU | Q50UDEHCPU | Q50UDEHCPU |
Q01UCPU | Q02CPU | Q02CPU-A |
Our advantage Products:
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
Shenzhen Wisdomlong Technology CO.,LTD
Contact person:Suki
Email:wtl2502keji@163.com
Skype:wtl2502
Company website:www.wtltian.com
Tel:+86-13268302140
temperature protection function |