Shenzhen Wisdomlong Technology CO.,LTD

Shenzhen Wisdomlong Technology CO.,LTD Work hard and best service for you!

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Redundant Power Supply Module /

Processor Type Redundant Power Supply Module TSX QUANTUM 140 CRP 932 00

Contact Now
Shenzhen Wisdomlong Technology CO.,LTD
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissBecky
Contact Now

Processor Type Redundant Power Supply Module TSX QUANTUM 140 CRP 932 00

Ask Latest Price
Video Channel
Brand Name :Schneider
Model Number :140 CRP 932 00
Place of Origin :FR
MOQ :1
Price :negotiable
Payment Terms :T/T, Western Union
Supply Ability :100
Delivery Time :2-3 work days
Packaging Details :New in original box
Brand :Schneider
Model :140 CRP 932 00
Palce of Origin :FR
Type :Processor/Controller
Bus Current :750 mA
module format :Standard
Channels :2
Weight :0.37 kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Redundant Power Supply Module SCHNEIDER TSX QUANTUM 140 CRP 932 00

  • Description: Remote Interface Module Head
  • Power Dissipation in W: 3 W 2 Channels
  • Bus Current Requirement: 750 mA 2 Channels
  • Module Format: Standard
  • Range of Product: Modicon Quantum automation platform
  • Product Compatibility: Symax (any mix), Quantum 200/500/800 series
  • Drops/Network: <= 31
  • Isolation Voltage: 500 V DC coaxial center and ground
  • Electrical Connection: 2 female connectors F elbowed with redundanct cable


OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
Similar Products
  • 140 CRP 932 0O
  • 140 CRP 932 O0
  • 140 CRP 932 OO
  • 140 CRP 93Z 00
  • 140 CRP 93Z 0O
  • 140 CRP 93Z O0
  • 140 CRP 93Z OO
  • 14O CRP 932 00
  • 14O CRP 932 0O
  • 14O CRP 932 O0
  • 14O CRP 932 OO
  • 14O CRP 93Z 00
  • 14O CRP 93Z 0O
  • 14O CRP 93Z O0
  • 14O CRP 93Z OO
  • I40 CRP 932 00
  • I40 CRP 932 0O
  • I40 CRP 932 O0
  • I40 CRP 932 OO
  • I40 CRP 93Z 00
  • I40 CRP 93Z 0O
  • I40 CRP 93Z O0
  • I40 CRP 93Z OO
  • I4O CRP 932 00
  • I4O CRP 932 0
  • 140CRP93200-A
  • 140CRP93200-B
  • 140CRP93200-C
  • 140CRP93200-D
  • 140CRP93200-E
  • 140CRP93200-F
  • 140CRP93200-G
  • 140CRP93200-H
  • 140CRP93200-I
  • 140CRP93200-J
  • 140CRP93200-K
  • 140CRP93200-L
  • 140CRP93200-M
  • 140CRP93200-N
  • 140CRP93200-O
  • 140CRP93200-P
  • 140CRP93200-Q
  • 140CRP93200-R
  • 140CRP93200-S
  • 140CRP93200-T
  • 140CRP93200-U
  • 140CRP93200-V
  • 140CRP93200-W
  • 140CRP93200-X
  • 140CRP93200-Y
  • 140CRP93200-
  • 140CRP93200 REMOTE I/O HEAD S908 2CH COMM Modicon Quantum 140-CRP
  • Manufacturer: Modicon Quantum
  • Series: Communications
  • This 140-CRP-932-00 may qualify for our exchange for credit program.

Open the Parameter Configuration

This table shows the steps required to open the parameter configuration

1 Call the Bus Editor

2 Select the module

3 Click on the right mouse button

Result: A shortcut menu is opened

Processor Type Redundant Power Supply Module TSX QUANTUM 140 CRP 932 00

4 Select Open Module

Result: The module opens with the parameter configuration window

Introduction

The numbering of channels of an I/O module usually starts with 1 and counts up to the maximum number of supported channels. The software however starts numbering with a 0 for the least significant bit in a word (LSB). The Quantum I/O modules have their lowest channel mapped to the most significant bit (MSB). The following figure shows the mapping of I/O channels related to the bits in a word:.

Word Addressing Versus Bit Addressing

Mainly discrete I/O modules can be configured to deliver their I/O data either in word format or in bit format. This can be selected during configuration by selecting either %IW (%MW) or %I (%M). If you need to access a single bit from an I/O module configured to use an I/O word, you can use the syntax %word.bit. The following table gives you the connection between I/O point number and the associated I/O address in bit and word addressing. The table shows a 32-point input module in the main rack, slot 4 configured with starting address %I1 or %IW1:

Processor Type Redundant Power Supply Module TSX QUANTUM 140 CRP 932 00

I/O channel Bit address (flat addressing) Bit address (topological addressing) Bit address extracted from word (flat addressing) Bit address extracted from word (topological addressing) 1 %I1 %I1.4.1[.0] %IW1.15 %IW1.4.1.1.15 2 %I2 %I1.4.2[.0] %IW1.14 %IW1.4.1.1.14 3 %I3 %I1.4.3[.0] %IW1.13 %IW1.4.1.1.13 • • • 15 %I15 %I1.4.15[.0] %IW1.1 %IW1.4.1.1.1 16 %I16 %I1.4.16[.0] %IW1.0 %IW1.4.1.1.0 17 %I17 %I1.4.17[.0] %IW2.15 %IW1.4.1.2.15 18 %I18 %I1.4.18[.0] %IW2.14 %IW1.4.1.2.14 • • • 31 %I31 %I1.4.31[.0] %IW2.1 %IW1.4.1.2.1 32 %I32 %I1.4.32[.0] %IW2.0 %IW1.4.1.2.0

Addressing Module Status Data

In addition to possible channel related diagnostics data, a module related status byte may be used. The status information of all modules in a Drop is administered by a table of %IW words. The starting address of this table can be entered in the configuration screen for the Drop. This information is not accessible through topological addressing. NOTE: The status information is only available if the module supports a status byte. For the meaning of the status byte check the module descriptions. Example of a Drop configuration screen with the starting address of the status table set to 100:

The following illustration shows how one word of the table conveys the status information for two modules:

Processor Type Redundant Power Supply Module TSX QUANTUM 140 CRP 932 00

Error Codes Table

Number of Blinks Code Error Slow (steady) 0000 Requested Kernal Mode 2 6820 hcb frame pattern error 6822 head cntrl blk diag error 6823 mod personality diag error 682A fatal start I/O error 682B bad read I/O pers request 682C bad execute diag request 6840 ASCII input xfer state 6841 ASCII output xfer state 6842 I/O input comm. state 6843 I/O output comm. state 6844 ASCII abort comm. state 6845 ASCII pause comm. state 6846 ASCII input comm. state 6847 ASCII output comm. state 6849 building 10 byte packet 684A building 12 byte packet 684B building 16 byte packet 684C illegal I/O drop number 3 6729 984 interface bus ack stuck high 4 6616 coax cable initialization error 6617 coax cable dma xfer error 6619 coax cable dumped data error 681A coax cable DRQ line hung 681C coax cable DRQ hung 5 6503 RAM address test error 6 6402 RAM data test error

Inquiry Cart 0