Shenzhen Wisdomlong Technology CO.,LTD

Shenzhen Wisdomlong Technology CO.,LTD Work hard and best service for you!

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Pressure Temperature Transmitter /

STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

Contact Now
Shenzhen Wisdomlong Technology CO.,LTD
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissBecky
Contact Now

STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

Ask Latest Price
Brand Name :Honeywell
Model Number :STT850
Place of Origin :America
MOQ :1
Price :negotiable
Payment Terms :T/T
Supply Ability :100
Delivery Time :5-8 work days
Packaging Details :New in original box
brand :Honeywell
model :STT850
origin :America
Output :4-20 mA dc
version :HART ® (version 7.0)
Digital Accuracy :up to +/- 0.10 Deg C for RTD
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Pressure Temperature Transmitter STT850 SmartLine Digital Accuracy up to +/- 0.10 Deg C for RTD 4-20 mA dc

Introduction
Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures. The SmartLine family is also fully tested and compliant with Experion ® PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.


Best in Class Features:

Industry leading performance
oDigital Accuracy up to +/- 0.10 Deg C for RTD
o Stability up to +/- 0.01% of URL per year for ten years
o 125 mSec update time for single input models
o 250 mSec update time for dual input models

Reliable measurement
o Built in Galvanic Isolation
o Differential/Averaging/Redundant/Split Range measurements
o Dual Compartment Housing
o Sensor Break detection
o Comprehensive on-board diagnostic capabilities
o Full compliance to SIL 2/3 requirements.
o Available with 15 year warranty
o Supports Namur 107 Extended Diagnostics
o Supports Namur 89 Wire break
o Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not
available on DE units)

Lower Cost of Ownership
o Universal input
o Dual sensor option
o Multiple local display capabilities
o Modular construction
o External zero, span, & configuration capability
o Polarity insensitive loop wiring
o Digital Output Option (only available with HART)

Communications/Output Options:
o 4-20 mA dc
o Honeywell Digitally Enhanced (DE)
o HART ® (version 7.0)
o FOUNDATION™ Fieldbus compliant to ITK 6.1.2 All transmitters are available with the above listed
communications protocols.



Instructions:
Make selections from all Tables Key through XIII using column below the proper arrow. Asterisk indicates availability. Letter (a) refer to restrictions highlighted in the restrictions table. Tables delimited w ith dashes.
STT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA DcSTT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA DcSTT850 Honeywell Pressure Transmitter , Pressure Indicator Transmitter 4-20 MA Dc

Performance under Rated Conditions – All Models

Parameter Description
Input Span Adjustment Range No limits to adjustments within the maximum range except minimum span limit of 1 engineering unit
Analog Output Digital Communications:

Two-wire, 4 to 20 mA (HART & DE Transmitters only)
Honeywell DE, HART 7 protocol or FOUNDATION Fieldbus ITK 6.1.2 compliant All transmitters, irrespective of protocol have polarity insensitive connections.

Output Failure Modes (HART/DE only)

Honeywell Standard: NAMUR NE 43 Compliance:
Normal Limits: 3.8 – 20.8 mA 3.8 – 20.5 mA
Failure Mode: ≤ 3.6 mA and ≥ 21.0 mA ≤ 3.6 mA and ≥ 21.0 mA

Output Accuracy (HART/DE only) ±0.005 % span
Supply Voltage Effect 0.005 % span per volt.
Transmitter Turn on Time (includes power up & test algorithms) HART or DE: 2.5 sec. Foundation Fieldbus: Host dependant
Analog Input

Stability: 0.01% of URL per Year for 10 years
Maximum Lead Wire Resistance:
Thermocouples: 50 ohms per leg
RTD (all except Pt15) and Ohms: 50 ohms per leg
RTD Pt25: 10 ohms per leg

Response Time
(delay + time constant)

DE/HART Analog Output FOUNDATION Fieldbus
Single Input: 130 - 230 mSec Host Dependant
Dual Input: 305 - 455 mSec Host Dependant

Update time

125 mSec for single input units
250 mSec for dual input units

Damping Time Constant

HART: Adjustable from 0 to 102 seconds in 0.1 increments. Default: 0.50 seconds
DE: Discrete values 0.0, 0.3, 0.7, 1.5, 3.1, 6.3, 12.7, 25.5, 51.1, 102.3 seconds.
Default: 0.3 seconds

Ambient Temperature Effect

Digital Accuracy
For RTD Inputs: 0.0015 °C/°C
For T/C Inputs: 0.005 °C/°C
Output D/A: 0.0005 % of span/°C

Cold Junction Accuracy ±0.25 °C
Total Reference Accuracy

Digital Mode
Digital Accuracy + C/J Accuracy (T/C input types only)
Analog Mode (HART/DE only)
Digital Accuracy + Output D/A Accuracy + C/J Accuracy (T/C input types only) Example: Transmitter in Analog Mode with Pt100 sensor and 0 to 200°C range Total Reference Accuracy = 0.10°C + (200 °C / 100 %) * 0.005 % = 0.11 °C

Sensor Burnout Burnout detection is user selectable. Upscale or down scale with critical status message. For RTD or ohm type inputs; broken wire/wires will be indicated
Digital Output

Contact Rating
Voltage: +12 to +30 Vdc.
Current: 40mA maximum (controlled by load resistance)
Low Level: 0 to 2 Vdc

Vibration Effect Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21 displacement/3g max acceleration)
Electromagnetic Compatibility IEC 61326-3-1
Isolation 2000 Vdc (1400Vrms) Galvanic isolation between inputs and output.
Stray Rejection

Common Mode
AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 ohms) or ± 1 LSB (least significant bit) whichever is greater with line voltage applied.
DC: 120 dB (with maximum source impedance of 50 ohms) or a ±1 LSB whichever is greater with 120 Vdc applied.
DC (to 1 KHz): 50 dB (with maximum source of impedance of 50 ohms) or ±1 LSB whichever is greater with 50 Vac applied. Norma l Mode
AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum)

EMC Compliance EN 61326-1 and EN 61326-3-1 (SIL)
Lightning Protection Option

Leakage Current: 10 uA max @ 42.4 VDC 85 °C
Impulse rating: 8/20 uS 5000 A (>10 strikes) 10000 A (1 strike min.)
10/1000 uS 200 A (> 300 strikes)